ar71xx: fix LED configuration on the RB-750

SVN-Revision: 29666
This commit is contained in:
Gabor Juhos 2012-01-05 18:08:28 +00:00
parent c3b763ac77
commit 232eb83f74

View File

@ -106,9 +106,13 @@ alfa-nx)
set_led_netdev "lan" "LAN" "alfa:green:led_3" "eth1"
;;
rb750)
rb-750)
set_led_default "act" "act" "rb750:green:act" "1"
set_led_netdev "port1" "port1" "rb750:green:port1" "eth1"
set_led_switch "port2" "port2" "rb750:green:port2" "switch0" "0x10"
set_led_switch "port3" "port3" "rb750:green:port3" "switch0" "0x08"
set_led_switch "port4" "port4" "rb750:green:port4" "switch0" "0x04"
set_led_switch "port5" "port5" "rb750:green:port5" "switch0" "0x02"
;;
dir-825-b1)