d4de9f72f3
VGV7510KW2 with VRX288 v1.2 has brnboot 1.8 installed. Starting with this brnboot version, the "GPHY Clock Source" isn't set anymore by brnboot, with the result that xrx200-net fails to probe/initialize the phys. Use the phy clock source device tree binding to specify the clock source. Signed-off-by: Mathias Kresin <openwrt@kresin.me> SVN-Revision: 49284
65 lines
1.1 KiB
Plaintext
65 lines
1.1 KiB
Plaintext
/dts-v1/;
|
|
|
|
/include/ "VGV7510KW22.dtsi"
|
|
|
|
/ {
|
|
sram@1F000000 {
|
|
cgu@103000 {
|
|
lantiq,phy-clk-src = <0x2>;
|
|
};
|
|
};
|
|
|
|
fpi@10000000 {
|
|
localbus@0 {
|
|
nor-boot@0 {
|
|
partitions {
|
|
partition@0 {
|
|
label = "Boot";
|
|
reg = <0x00000 0x40000>;
|
|
read-only;
|
|
};
|
|
|
|
partition@40000 {
|
|
label = "Configuration";
|
|
reg = <0x40000 0x40000>;
|
|
read-only;
|
|
};
|
|
|
|
partition@80000 {
|
|
label = "Certificate";
|
|
reg = <0x80000 0x20000>;
|
|
read-only;
|
|
};
|
|
|
|
partition@a0000 {
|
|
label = "Special_Area";
|
|
reg = <0xa0000 0x20000>;
|
|
read-only;
|
|
};
|
|
|
|
partition@c0000 {
|
|
compatible = "brnboot,root-selector";
|
|
label = "Primary_Setting";
|
|
reg = <0xc0000 0x20000>;
|
|
read-only;
|
|
};
|
|
|
|
partition@e0000 {
|
|
label = "Code_Image_0";
|
|
reg = <0xe0000 0x780000>;
|
|
brnboot,root-id = <0x00>;
|
|
read-only;
|
|
};
|
|
|
|
partition@860000 {
|
|
label = "Code_Image_1";
|
|
reg = <0x860000 0x780000>;
|
|
brnboot,root-id = <0x01>;
|
|
read-only;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
};
|
|
};
|