This patch configures the correct ath9k WLAN LED polarity for the TDW8970,
and for the TDW8980 as well.
Signed-off-by: Vittorio Gambaletta <openwrt@vittgam.net>
SVN-Revision: 47969
Fixes: commit f17e56eff5b9 ("gcc: remove version 4.6, it is no longer needed")
CC: Felix Fietkau <nbd@openwrt.org>
Signed-off-by: Sedat Dilek <sedat.dilek@gmail.com>
SVN-Revision: 47965
All supported kernels require patching ledtrig-netdev in the same way,
so it's safe to just move these changes to the base version of this
driver. We needed these patches for some old kernels 2.6.36 and 3.11.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
SVN-Revision: 47962
In r45970 the MAC swap handling was made opt-in, however some boards
have been forgotten during the conversion. Since the reference design
uses this MAC swapping, and pretty much all known boards using this chip
seem to do so too, enabling the swapping is a more reasonable default
than leaving it disabled.
Change the code to still allow boards to opt-out of this.
Signed-off-by: Felix Fietkau <nbd@openwrt.org>
SVN-Revision: 47956
Changed option nonwildcard from --bind-interfaces into --bind-dynamic.
With this, Dnsmasq binds the address of individual interfaces, allowing multiple
dnsmasq instances, but if new interfaces or addresses appear, it automatically
listens on those. This makes dynamically created interfaces work in the same way as
the default, but allows also use of other DNS-servers (like Named) at the same time
on diffirent interfaces where Dnsmasq is NOT configured, whereas with
--bind-interfaces will still reserve every interface even if not used and thus
disallowing use of any other DNS-program even on unused interfaces.
Tested-by: Vaasa Hacklab <info@vaasa.hacklab.fi>
Signed-off-by: Sami Olmari <sami@olmari.fi>
SVN-Revision: 47953
The following patch is to add ath79_register_m25p80_large, which sets
is_flash to false to support bit banging. This is needed on some 32MB+
SPI chips, such as the S25FL256S1
Signed-off-by: Chris R Blake <chrisrblake93@gmail.com>
SVN-Revision: 47952
This reverts r47245.
Linking to shared libraries under $STAGING_DIR_HOST{,/usr}/lib is harmful,
as these directories aren't added to LD_LIBRARY_PATH (see r47103 for an
explanation why LD_LIBRARY_PATH is not used).
Revert to static linking; in particular, this fixes the build of the python
bz2 module on OpenSUSE and Fedora (which in turn broke the build of
nodejs).
Signed-off-by: Matthias Schiffer <mschiffer@universe-factory.net>
SVN-Revision: 47950
The MR18 stores the ath9k eeprom values on the NAND.
This patch makes it possible to retrieve the images
from there.
Signed-off-by: Chris R Blake <chrisrblake93@gmail.com>
SVN-Revision: 47948
move all library includes and 'firmware already exists'
check to the top of the script.
Signed-off-by: Chris R Blake <chrisrblake93@gmail.com>
SVN-Revision: 47947
OpenWrt configuration part of support for the PowerCloud Systems
CR5000. The CR5000 is a dual-band 802.11n wireless router with
8MB flash, 64MB RAM, (unused on stock firmware) USB 2.0 port and
five port gigabit ethernet switch. The CR5000 was sold as
hardware for the Skydog cloud-managed router service.
Signed-off-by: Daniel Dickinson <openwrt@daniel.thecshore.com>
SVN-Revision: 47946
OpenWRt configuration part of support for the PowerCloud
Systems CR3000. The CR3000 is a 802.11n 2.4 GHz wireless router with
8MB flash, 64MB RAM, a four port gigabit ethernet switch, and a fast
ethernet wan port that was sold by PowerCloud Systems as
hardware for the Skydog cloud-managed router service.
Signed-off-by: Daniel Dickinson <openwrt@daniel.thecshore.com>
SVN-Revision: 47945
Openwrt configuration part of support for PowerCloud CAP324
Cloud AP. The CAP324 Cloud AP is a device sold by PowerCloud Systems
who's stock firmware (CloudCommand) provides 'cloud' based managment
of large numbers access points.
The CAP324 is a dual-band 802.11n wireless access point with 16MB flash
and 128MB RAM and single gigabit ethernet port. It can be powered via PoE
or a wall wart.
Signed-off-by: Daniel Dickinson <openwrt@daniel.thecshore.com>
SVN-Revision: 47944
Kernel part of support for the PowerCloud Systems CR5000. The
CR5000 is a dual-band 802.11n wireless router with 8MB flash,
64 MB RAM, (unused in stock firmware) USB 2.0 port, and five
port gigabit ethernet switch. The CR5000 was sold as hardware for
the Skydog cloud-managed router service.
Signed-off-by: Daniel Dickinson <openwrt@daniel.thecshore.com>
SVN-Revision: 47943
Image generation part of support for PowerCloud CR3000. The CR3000 is
a 802.11n 2.4 GHz wireless router with 8MB flash, 64MB RAM,
a four port fast ethernet switch, and a fast ethernet wan port which
was sold by PowerCloud Systems as hardware for the Skydog
cloud-managed router service.
Signed-off-by: Daniel Dickinson <openwrt@daniel.thecshore.com>
SVN-Revision: 47942
Image generation (and mtd partition) part of support for
PowerCloud CAP324 Cloud AP. The CAP324 Cloud AP is a device sold by
PowerCloud Systems who's stock firmware (CloudCommand) provides
'cloud' based managment of large numbers of access points.
The CAP324 is a dual-band 802.11n wireless access point with 16MB flash
and 128MB RAM and single gigabit ethernet port. It can be powered via
PoE or a power adaptor.
Signed-off-by: Daniel Dickinson <openwrt@daniel.thecshore.com>
SVN-Revision: 47941
Kernel part of support for the PowerCloud Systems CR5000. The
CR5000 is a dual-band 802.11n wireless router with 8MB flash,
64 MB RAM, (unused in stock firmware) USB 2.0 port, and five
port gigabit ethernet switch. The CR5000 was sold as hardware for
the Skydog cloud-managed router service.
Signed-off-by: Daniel Dickinson <openwrt@daniel.thecshore.com>
SVN-Revision: 47940
Kernel part of support for PowerCloud CR3000. The CR3000 is
a 802.11n 2.4 GHz wireless router with 8MB flash, 64MB RAM,
a four port fast ethernet switch, and a fast ethernet wan port which
was sold by PowerCloud Systems as hardware for the Skydog
cloud-managed router service.
Signed-off-by: Daniel Dickinson <openwrt@daniel.thecshore.com>
SVN-Revision: 47939
Kernel part of support for PowerCloud CAP324 Cloud AP.
The CAP324 Cloud AP was a device sold by PowerCloud Systems as hardware for
the CloudCommand service for 'cloud' based managment of large numbers
access points.
The CAP324 is a dual-band 802.11n wireless access point with 16MB flash
and 128MB RAM and single gigabit ethernet port. It can be powered via PoE
or a power adaptor.
Signed-off-by: Daniel Dickinson <openwrt@daniel.thecshore.com>
SVN-Revision: 47938
Commit r47866 dropped default values which were handling WAN interface
at port 0. Fix it by handling 2 more cases on NVRAM values.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
SVN-Revision: 47932
Using the JSON output option depends on json library so
add select json-c library when JSON output is selected.
Signed-off-by: Daniel Dickinson <openwrt@daniel.thecshore.com>
SVN-Revision: 47928
- 1.4.x has IPv6 support
- set C std explicitly due to gcc 5 changes/old code style of dante
- disable pam via configure vars since detection of without pam option
is broken (-lpam gets linked in if available)
- remove and refresh patches
only compile tested
Signed-off-by: Dirk Neukirchen <dirkneukirchen@web.de>
SVN-Revision: 47926
- tested on Beagleboard C4
- remove upstream patches
- disable THUMB mode on OMAP3 this increases binary size
(remove CONFIG_SYS_THUMB_BUILD)
- reduce SPL size by disabling EXT feature
(remove CONFIG_SPL_EXT_SUPPORT)
this fixes 2015.07 and 2015.10-rc3
Beagleboard C4 booting
which were broken by upstream commit
with id: bd2c4522c26d535515aebca52d27c004a7e0c05c
Arm THUMB mode is broken because of an yet unknown errata
see: http://lists.denx.de/pipermail/u-boot/2015-August/225793.html
- backport upstream fix that was introduced in 2015.10-rc5
and was not fixed in 2015.10 final
Signed-off-by: Dirk Neukirchen <dirkneukirchen@web.de>
SVN-Revision: 47924
since Kernel 3.14
408eccce net: ptp: move PTP classifier in its own file
found while bug search
thx olmari on IRC
Signed-off-by: Dirk Neukirchen <dirkneukirchen@web.de>
SVN-Revision: 47923
Based off of the GW2391-C, but with the following changes:
* 4x4in to 4x5in pcb
* flat panel connector for LED signals
Signed-off-by: Tim Harvey <tharvey@gateworks.com>
Signed-off-by: Pushpal Sidhu <psidhu@gateworks.com>
SVN-Revision: 47920
Principal purpose is to prevent the error message
ifxmips_ptm_vdsl.c:281:ptm_hard_start_xmit: not in showtime
which is printed at least once per second to the serial console, if the
ptm interface is not in showtime, but a processes already sends
packages over that interface. This happens for adsl as well as vdsl
over ptm.
It's pppd which sends packages over the ptm device before in showtime.
As far as I can see, pppd is started unconditionally since netif can
not gather the link status of the ptm network interface.
Signed-off-by: Mathias Kresin <openwrt@kresin.me>
SVN-Revision: 47917
This prevents the unconditionally start of pppd since netifd will be
triggered if the device goes into showtime. The same applies to lost
showtime as well.
In compare to the ptm driver, this changeset isn't strictly required,
since the "not in showtime" message is limited to the debug loglevel.
But it reduces the amount of ppp related messages significant.
Signed-off-by: Mathias Kresin <openwrt@kresin.me>
SVN-Revision: 47916